Request a Quote|Join our E-Mail List|Contact Us
HomeSearch: 
Advanced Search
 

Filters
Standard Diffraction Gratings
Monochromators & Modules
IR Laser Optics
  Ruled Wire Polarizer
  Holographic Wire Grid Polarizers
  Molecular Laser (ML) Gratings
  Grating End Reflectors for Dye Lasers
  Echelles Gratings
  Grazing Incidence Gratings
  Tunable Grating Filter
  Accessories
  Coatings and Specifications for ML Gratings
  OEM/Custom Design
  FAQ
  Catalog
Beam Splitters
SPF
Tunable Light Sources
IR Laser Optics - Holographic Wire Grid Polarizers

Holographic Wire Grid Polarizers
Overcoatings
Standard Sizes and Options
Highlights
Specifications

HOLOGRAPHIC WIRE GRID POLARIZERS
Working with experts in the field, Optometrics has developed a special holographic technique to produce Infrared Polarizers with sub-micron grid spacing. In the Companys holographic laboratory, an interferometrically generated interference pattern is produced from monochromatic light and exposed onto a photo-resist coated substrate. Once developed, the resist has a regular sinusoidal profile which is vacuum aluminized at an oblique angle to create the array of parallel conductors.

The fabrication of holographic wire grid polarizers permits the use of a wide variety of infrared materials that do not lend themselves to the ruling process. They are available with a spacing of 2700 grooves/mm for optimum short-wavelength efficiency.

Back to Top


OVERCOATINGS
Calcium Fluoride and Barium Fluoride have low refractive index (high Tx) values and do not require anti-reflective (AR) coatings.

Zinc Selenide has a high refractive index and transmission at specific wavelength regions which can be enhanced by an AR coating on the rear surface only. Zinc Selenide is usually optimized for transmission at specific laser lines, typically from 9 to 11 microns.

KRS-5 is not normally AR coated, because this would limit its broad transmission range, which is its primary advantage.
Germanium is AR/AR coated to maximize transmission @ 10.6 microns.

Back to Top


STANDARD SIZES AND OPTIONS
Holographic wire grid polarizers are currently available in a standard 25 mm diameter size, unmounted or mounted in a double protective ring, 38 mm diameter unmounted, 50 mm diameter mounted in a double protective ring and our newest line for FTIR Spectrometers in a 360° rotary mount with a 25 mm diameter clear aperture.

If your application requires a different size or shape, please contact us for price and delivery. OEM inquires are welcome.

Back to Top


HIGHLIGHTS

  • 2700 grooves/mm
  • On Calcium Fluoride (CaF2), Barium Fluoride (BaF2), Zinc Selenide (ZnSe), KRS-5 and Germanium (Ge)
  • For improved short wavelength performance
  • Extended infrared range
  • High transmission
  • High extinction ratios
  • 360° bench mountable, rotary stage for FTIR spectrometers
  • All polarizers can be mounted in a double protective ring

Back to Top


SPECIFICATIONS

  • Wire grid spacing 2700 grooves/mm (nominal)
  • Parallelism: ≤ 3 arc minutes
  • Substrate thickness 2 mm nominal
  • Ring thickness: ± 0.1 mm
  • Dimensional Tolerance: ±0.5 mm
Norminal Extinction Ratios
Material Wavelength(microns) Typical Extinction Ratio
CaF2 3
8
100
250
BaF2
3
10
100
300
ZnSe 3
10
100
300
KRS-5 3
15
100
200
Ge
(AR\AR)
10.6 200

 

 

CAUTION: The surface of a wire grid polarizer, like any diffraction grating, is extremely delicate. Nothing should ever be allowed to touch the surface of the polarizer. Handling, when necessary, should be by the edge only and with protected fingers. Careful removal of dust by gentle air flow is the only cleaning procedure recommended by Optometrics. Particular care should be used when handling KRS-5.

Unmounted
CATALOG NO. 5-8003 5-8103 5-8203 5-8303 5-8403 5-8004 5-8104 5-8204
SUBSTRATE ZnSe CaF2 BaF2 KRS-5 GE (AR/AR) ZnSe CaF2 BaF2
CLEAR
APERTURE
22.5 mm 22.5 mm 22.5 mm 22.5 mm 22.5 mm 25 mm 25 mm 25 mm
OUTSIDE
DIMENSIONS
25 mm dia. 25 mm dia. 25 mm dia. 25 mm dia. 25 mm dia. 29 mm dia. 29 mm dia. 29 mm dia.

* Prices are in USD and are list prices only.
 
Unmounted
CATALOG
NO
5-8304 5-8404 5-8011 5-8111 5-8211 5-8311 5-8411 5-8015 5-8115 5-8215 5-8315 5-8415
SUBSTRATE KRS-5 GE (AR/AR) ZnSe CaF2 BaF2 KRS-5 GE (AR/AR) ZnSe> CaF2 BaF2 KRS-5 GE (AR/AR)
CLEAR
APERTURE
25 mm 25 mm 34 mm 34 mm 34 mm 34 mm 34 mm 45 mm 45 mm 45 mm 45 mm 45 mm
OUTSIDE
DIMENSIONS
29 mm dia. 29 mm dia. 38 mm dia. 38 mm dia. 38 mm dia. 38 mm dia. 38 mm dia. 50 mm dia. 50 mm dia. 50 mm dia. 50 mm dia. 50 mm dia.

Price($)*

1,325 1,385 1,415 1,125 1,195 1,625 1,625 1,795 1,475 2,195 2,195 2,650

* Prices are in USD and are list prices only.

Mounted (Protective Double Ring)
CATALOG NO. 5-8001 5-8101 5-8201 5-8301 5-401 5-8031 5-8131
SUBSTRATE ZnSe CaF2 BaF2 KRS-5 GE (AR/AR) ZnSe CaF2
CLEAR
APERTURE
18 mm 18 mm 18 mm 18 mm 18 mm 25 mm 25 mm
OUTSIDE
DIMENSION
25 mm dia. 25 mm dia. 25 mm dia. 25 mm dia. 25 mm dia. 35 mm dia. 35 mm dia.
RING THICKNESS
mm
5.0 5.0 5.0 5.0 5.0 5.0 5.0

PRICE($)*

1,100 895 1,075 1,195 1,275 1,325 1,110

* Prices are in USD and are list prices only.
 
Mounted (Protective Double Ring)
CATALOG NO. 5-8231 5-8331 5-8021 5-8121 5-8221 5-8321 5-8421
SUBSTRATE BaF2 KRS-5 ZnSe CaF2 BaF2 KRS-5 GE (AR/AR)
CLEAR
APERTURE
25 mm 25 mm 34 mm 34 mm 34 mm 34 mm 34 mm
OUTSIDE
DIMENSION
35 mm dia. 35 mm dia. 50 mm dia. 50 mm dia. 50 mm dia. 50 mm dia. 50 mm dia.
RING THICKNESS
mm
5.0 5.0 6.0 6.0 6.0 6.0 6.0

PRICE($)*

1,275 1,535 1,540 1,250 1,300 1,400 1,785

* Prices are in USD and are list prices only.

 
Mounted in 3600 Rotary Mount
with adapter, post and breadboard screws suitable for breadboards, bench mounting and FTIR spectrometer applications.
CATALOG NO. 5-8005 5-8105 5-8205 5-8305 5-8405
SUBSTRATE ZnSe CaF2 BaF2 KRS-5 GE (AR/AR)
CLEAR
APERTURE
25 mm 25 mm 25 mm 25 mm 25 mm

PRICE($)*

2,115 1,855 1,990 2,225 2,450
 
* Prices are in USD and are list prices only.

 
 
Mounted in 3600° Rotary Mount
with adapter, post and breadboard screws suitable for breadboards, bench mounting and FTIR spectrometer applications.
CATALOG NO. 5-2146 5-2147 5-2148
DESCRIPTION Rotary stage. Bench mountable stage allows 360 rotation of wire grid polarizer in 25 mm diameter protective ring. Rotary stage. Bench mountable stage allows 360 rotation of wire grid polarizer  in 50 mm diameter protective ring. Adapter. Allows 15 mm square wire grid polarizers to be used in 5-2146 rotary stage.

PRICE($)*

230.00 385.00 80.00

* Prices are in USD and are list prices only.

 
 
 
         Home   |    Products    |    Support    |   Literature    |    Employment    |    Contact Us    |    About Us  
 

Optometrics 8 Nemco Way, Stony Brook Industrial Park, Ayer, MA 01432 USA
Phone: (978) 772-1700  Fax: (978) 772-0017

© 2007 Optometrics. All rights reserved   |   Privacy Policy
Website design by Versacor