Any standard Optometrics grating is available with either P-type or CW-type construction, for higher damage threshold performance.
Damage Thresholds: (no damage threshold minimums apply to gratings with an overcoat)
Standard Replica Gratings: Pulsed: 350 millijoules/cm2 @ 200 ns CW: 40 watts/cm2
P-Type Replica Gratings: (pulsed type) Pulsed: 3.5 joules/cm2 @ 200 ns CW: 80 watts/cm2
CW-Type Replica Gratings: (for continuous high power applications) Pulsed: 3.5 joules/cm2 @ 200 ns CW: 250 watts/cm2
Coatings Regardless of size, the additional cost per piece is:
Gold Overcoat (part number AU-3) $60.00 Aluminum Magnesium Fluoride (part number ALMG-3) $55.00
Note: While a gold overcoat can increase reflectivity, any overcoating may reduce the damage threshold by a factor of two or more. |
|
|
|